مشخصات پژوهش

صفحه نخست /Differential Pulse Adsorption ...
عنوان Differential Pulse Adsorption Stripping Voltammetric Determination of Copper(II) with 2-Mercaptobenzimidazol at a Hanging Mercury-Drop Electrode
نوع پژوهش مقاله چاپ‌شده در مجلات علمی
کلیدواژه‌ها 2-mercaptobenzimidazole,copper
چکیده Copper(II) was selectively accumulated on a hanging mercury-drop electrode by using 2-mercaptobenzimidazole. Ensuing measurements were carried out by differential pulse adsorption stripping voltammetry. Factors affecting the accumulation, reduction, and stripping steps were investigated and a procedure was developed. The optimum conditions for the analysis of copper were pH 5.0, 5.33 x 10-5 M 2-mercaptobenzimidazole and an accumulation potential of -0.10 V (vs. Ag/AgCl). A linear range was obtained in the concentration range 0.2 - 100 ng/ml with a 90 s accumulation time and a scan rate of 16 mV/s. For ten successive determinations of 1.0, 20.0 and 70.0 ng/ml copper(II), relative standard deviations of 4.2, 3.5 and 2.8%, respectively, were obtained. The developed method was applied to the determination of copper in commercial salts and aluminium alloys.
پژوهشگران علی اصغر انصافی (نفر اول)، شهریار عباسی (نفر دوم)، حسن رحیمی منصور (نفر سوم)، ایرج محمد پور بالترک (نفر چهارم)